CCSXC - 420 VOC TEFLON WHITE UNTINTED, 23T3-10

  • MSDS: CCSXC
  • Manufacturer: DEXTER CORP
  • Product Name: 420 VOC TEFLON WHITE UNTINTED, 23T3-10
  • National Stock Number: 8010-01-292-8892
Product Identification

Product ID:420 VOC TEFLON WHITE UNTINTED, 23T3-10
MSDS Date:12/05/1995
FSC:8010
NIIN:01-292-8892
MSDS Number: CCSXC

Responsible Party
DEXTER CORP
ONE EAST WATER ST
WAUKEGAN, IL 60085
US

Emergency Phone: 708-623-4200

Info Phone: 708-623-4200

Preparer: J SCARBALLS

Cage: 57294

Contractor
DIVERSITY WATER TECHNOLOGIES INC
200 CHAGRIN FALLS, OH 44022 US

Telephone: 216-247-5000

Cage: 57294

Ingredients

SILICA, CRYSTALLINE - CRISTOBALITE; (CRYSTALLINE SILICA

CAS: 14464-46-1

RTECS: VV7325000

Fraction By Weight: <10%

OSHA PEL SEE TABLE Z-3

ACGIH TLV: 0.05 MG/M3 RDUST


8.0 @

CAS: 123-86-4

RTECS: AF7350000

Fraction By Weight: 10-20%

OSHA PEL 150 PPM

ACGIH TLV: 150 PPM/200STEL

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


2.14 @ 20C

CAS: 110-43-0

RTECS: MJ5075000

Fraction By Weight: 10-20%

OSHA PEL 100 PPM

ACGIH TLV: 50 PPM


ACETIC ACID, 2-METHOXY-1-METHYLETHYL ESTER; (1-METHOXY

CAS: 108-65-6

RTECS: AI8925000

Fraction By Weight: <10%

OSHA PEL N/K

ACGIH TLV: N/K


3); (ALUMINUM OXIDE) (SARA 313)

CAS: 1344-28-1

RTECS: BD1200000

Fraction By Weight: 6-7%

OSHA PEL 15 MG/M3 TDUST

ACGIH TLV: 10 MG/M3 TDUST


0.00003

CAS: 7439-92-1

RTECS: OF7525000

Fraction By Weight: <0.01%

OSHA PEL SEE 1910.1025

ACGIH TLV: 0.15MG/M3 DUST

EPA Report Quantity: 1 LB

DOT Report Quantity: 1 LB

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO
Health Hazards Acute and Chronic:ACUTE:OVER EXPOSURE BY INHALATION MAY
CAUSE IRRITATION OF THE RESPIRATORY TRACT, HEADACHE, DIZZINESS OR
DROWSINESS. SKIN OR EYE CONTACT:IRRITANT TO THE EYES AND SKIN.
CHRONIC:LEAD APPEARS ON THE NAVY OCCUPATIONAL CHEMICAL
REPRODUCTIVE HAZARDS LIST. SEEK CONSULTATION FROM APPROPRIATE
HEALTH (EFTS OF OVEREXP)
Explanation of Carcinogenicity:SILICA, CRYSTALLINE-CRISTOBALITE:IARC
MONOGRAPHS, SUPP, VOL 7, PG 341, 1987:GROUPS 2A. NTP 7TH ANNUAL RPT
ON (SUPP DATA)
Effects of Overexposure:HLTH HAZS:PROFESSIONALS CONCERNING LATEST
HAZARD LIST INFORMATION AND SAFE HANDLING AND EXPOSURE INFORMATION
. THOSE HAZARDOUS MATERIALS LISTED IN INGREDIENTS MAY AFFECT THE
FOLLOWING ORGANS:RES PIRATORY TRACT, CENTRAL NERVOUS SYSTEM,KIDNEYS
AND REPRODUCTIVE SYSTEM.
Medical Cond Aggravated by Exposure:UNKNOWN AT THIS TIME.

First Aid

First Aid:INHALATION:REMOVE FROM EXPOSURE. EYE CONTACT:FLUSH
IMMEDIATELY WITH LARGE AMOUNTS OF RUNNING WATER FOR AT LEAST 15
MINUTES. SKIN CONTACT:REMOVE CONTAMINATED CLOTHING AND WASH SKIN
WITH SOAP AND WATER. INGESTION:DRINK WATER. IF NECESSARY, CONSULT
A PHYSICIAN FOR ANY OF THESE CONDITIONS.

Fire Fighting

Flash Point Method:SCC
Flash Point:75.0F,23.9C
Lower Limits:1.11%
Extinguishing Media:USE WATER FOG, FOAM, DRY CHEMICAL OR CARBON
DIOXIDE.
Fire Fighting Procedures:WEAR NIOSH APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT .
Unusual Fire/Explosion Hazard:NONE SPECIFIED BY MANUFACTURER.

Accidental Release

Spill Release Procedures:REMOVE ALL SOURCES OF IGNITION, AVOID
BREATHING VAPORS, VENTILATE AREA, AND REMOVE WITH INERT ABSORBENT
AND NON-SPARKING TOOLS. DISPOSE OF IN ACCORDANCE WITH LOCAL, STATE
AND FEDERAL REGULATIONS. BEFO RE ATTEMPTING TO CELAN UP, SEE
HAZARDOUS INGS.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:DO NOT TAKE INTERNALLY. CONTAINERS
SHOULD BE GROUNDED WHEN POURING. AVOID FREE FALL OF LIQUID IN
EXCESS OF A FEW INCHES.
Other Precautions:MAKE SURE THE DRUM IS COMPLETELY EMPTY BEFORE
ATTEMPTING TO WELD OR BRAZE. THE DRUM SHOULD BE INDUSTRIALLY
CLEANED PRIOR TO REUSE. DO NOT FLAME CUT, BRAZE OR WELD WITHOUT A
NIOSH APPRVD RESP OR APPROP VENT. KEEP CNTNR CLSD WHEN NOT IN USE.

Exposure Controls

Respiratory Protection:WHERE GEN DILUTION/LOC EXHST FAILS TO ADEQ
DILUTE TWA/PEL OF MATL, THEN RESP PROT SHOULD BE USED AS
FOLLOWS:I/A/W 29 CFR 1910.134, USE NIOSH APPRVD AIR LINE TYPE
RESPS/HOODS FOR ENCLSD & CONFINED AREA S. AIR PURIFYING RESPS MAY
(SUPDAT)
Ventilation:PROVIDE GENERAL DILUTION OR LOCAL EXHAUST VENT TO KEEP TWA
AND LEL BELOW ACCEPTABLE LIMS AND TO REMOVE DECOMP PRODS.
Protective Gloves:CHEMICAL RESISTANT GLOVES.
Eye Protection:ANSI APPROVED CHEM WORKERS GOGGS .
Other Protective Equipment:ANSI APPROVED EMERGENCY EYE WASH AND DELUGE
SHOWER .
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
EXPLAN OF CARCIN:CARCINOGENS. 1994:ANTICIPATED TO BE CARCINOGEN.
ANIMAL:LUNG. RESP PROT:BE USED FOR OTHER AREAS.

Chemical Properties

Boiling Pt:B.P. Text:>200F,>93C
Vapor Pres:SEE INGS
Vapor Density:HVR/AIR
Spec Gravity:1.41
VOC Grams/Liter:3.8

Stability

Stability Indicator/Materials to Avoid:YES
NONE SPECIFIED BY MANUFACTURER.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:FUMES MAY CONTAIN CARBON MONOXIDE AND
OXIDES OF NITROGEN. MAY PRODUCE HAZ FUMES WHEN HEATED TO DECOMP AS
IN WELDING.

Disposal

Waste Disposal Methods:DISPOSAL MUST BE I/A/W FEDERAL, STATE & LOCAL
REGULATIONS . DOT REPORTABLE QUANTITY:5000 GALLONS OR GREATER OF
PRODUCT:BUTYL ACETATE.

Other Information

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.